An advertisement generator (a.k.a. genset) will last for decades, as long as it’s properly maintained. Although a generator has few moving parts, it has sensitive components that require regular attention. Complete genset maintenance requires different measures to be performed on different schedules. If you need a agenda for these measures, here’s a basic checklist for heavy duty diesel generators maintenance with a daily, monthly, semiannual, and annual basis.

Daily Measures

Diesel generators should obtain the following measures every day:

General inspection – Look into the genset for loose parts, signs of corrosion on parts, traces of carbon, and mud increase.
Coolant heater check – Ensure that the coolant heater is securely in position and inspect it for signs and symptoms of wear.
Oil check – check the oil level and add oil as necessary.
Fuel check – confirm the fuel level and add fuel as necessary.
Charge-air piping check – be certain the charge-air piping is connected securely to the radiator and inspect it for warning signs of wear.
Maintenance personnel commonly carry out the measures above. Generator technicians also can perform them as part of a scheduled service agreement.

Weekly Measures

Diesel generators should have the following measures every week:

Air cleaner check – Check the home air cleaner for debris and fix it as necessary.
Wall charger check – Look into the float voltage reading for the battery charger and adjust the voltage as necessary.
Fuel Filter Drain – Drain water in the bottom in the fuel filter housing.
Fuel Tank Drain – Drain the river through the bottom in the fuel tank until the diesel fuel appears.
Many facilities have generator technicians perform weekly measures with a generator maintenance checklist. If building maintenance personnel perform them, they should have training in generator maintenance.

Monthly Measures

Diesel generators must have the following measures performed on a monthly basis:

Coolant concentration check – Take a sample from the coolant having a hydrometer and check its concentration by talking about the service manual from the manufacturer.
Drive belt tension check – Look into the belt for proper tension and inspect it for indications of wear.
Exhaust condensate drain – Drain the condensate from the condensate trap.
Battery check – Check the charge about the starting battery and examine the connections for looseness and corrosion.
As the correct power coolant within an outdoor generator could possibly be relying on climate, a generator technician that are experts in emergency power equipment should perform the coolant concentration check.

Semiannual Measures

Diesel generators must have these measures performed with a semiannual basis:

Oil and filter change – Switch the oil and oil filter, whether or not the genset has been employed in the non-simulated power outage.
Coolant filter change – Replace the coolant filter, no matter if the genset has been used within a non-simulated power outage.
Crankcase breather cleaning – Clean the crankcase breather in line with the service manual from the manufacturer.
Air cleaner element change – Replace the air cleaner element, no matter the a higher level debris accumulation.
Radiator hose check – Look at the connection with the radiator hoses and inspect them for warning signs of wear.
Fuel filter change – Alter the fuel filter, regardless of the level of sediment accumulation.
Generator technicians should perform measures above.

Annual Measures

The genset should have a complete annual cleaning of their air conditioning.

Conclusion

The measures above are needed to get a diesel generator to stay in excellent condition. By them in to a generator maintenance checklist, it is possible to prepare the generator in your facility for one more power outage.