A commercial generator (a.k.a. genset) can last for decades, as long as it is properly maintained. Although generators has few moving parts, it has sensitive components that require regular attention. Complete genset maintenance requires different measures to be performed on several schedules. If you want a schedule for performing these measures, below is a basic checklist for diesel generator maintenance on the daily, monthly, semiannual, and annual basis.
Daily Measures
Diesel generators should obtain the following measures on a daily basis:
General inspection – Check the genset for loose parts, signs of corrosion on parts, traces of carbon, and dirt increase.
Coolant heater check – Guarantee the coolant heater is securely in position and inspect it for signs of wear.
Oil check – look into the oil level and add oil as necessary.
Fuel check – check the fuel level and add fuel as necessary.
Charge-air piping check – make sure the charge-air piping is connected securely for the radiator and inspect it for warning signs of wear.
Maintenance personnel commonly carry out the measures above. Generator technicians can also perform them within a scheduled service agreement.
Weekly Measures
Diesel generators should receive the following measures every week:
Air cleaners check – Look at the air cleaners for debris and fix it as necessary.
Battery charger check – Confirm the float voltage reading around the 12v charger and adjust the voltage as necessary.
Fuel Filter Drain – Drain the water from the bottom with the fuel filter housing.
Fuel Tank Drain – Drain water in the bottom in the fuel tank until the diesel fuel appears.
Many facilities have generator technicians perform weekly measures with a generator maintenance checklist. If building maintenance personnel perform them, they ought to have lessons in generator maintenance.
Monthly Measures
Diesel generators really should have the subsequent measures performed from month to month:
Coolant concentration check – Take a sample of the coolant using a hydrometer and appearance its concentration by discussing the service manual from your manufacturer.
Drive belt tension check – Look at the belt for proper tension and inspect it for signs of wear.
Exhaust condensate drain – Drain the condensate from your condensate trap.
Battery check – Look at the charge for the starting battery and examine the connections for looseness and corrosion.
As the correct energy coolant in a outdoor generator might be relying on climate, an electrical generator technician that specializes in emergency power equipment should do the coolant concentration check.
Semiannual Measures
Diesel generators really should have the subsequent measures performed over a semiannual basis:
Oil and filter change – Switch the oil and oil filter, no matter whether the genset was used in a non-simulated power outage.
Coolant filter change – Replace the coolant filter, regardless of whether the genset was used inside a non-simulated power outage.
Crankcase breather cleaning – Clean the crankcase breather based on the service manual in the manufacturer.
Home air cleaner element change – Replace the home air cleaner element, no matter the degree of debris accumulation.
Radiator hose check – Look at the connection with the radiator hoses and inspect them for signs and symptoms of wear.
Fuel filter change – Affect the fuel filter, no matter the level of sediment accumulation.
Generator technicians should perform measures above.
Annual Measures
The genset really should have a comprehensive annual cleaning of the company’s air conditioning.
Conclusion
The measures above are expected for a diesel generator to stay in excellent condition. By them into a generator maintenance checklist, it is possible to prepare the generator with your facility for an additional power outage.
More details about generator maintenance check our web site